Application Wide Settings - This lists settings currently defined in the Application Settings dialog box.
Release for scanning - Yes or No, depending on if this is checked in the dialog box.
User exit program name - If a name is defined in the dialog box, it is displayed. If not, None.
Inverted transport printing - Yes or No, depending on if this is checked in the dialog box.
Limit Bitone Dynamic Threshold (For Image Scanners Only) - Yes or No, depending on if this is checked in the dialog box.
Scanner Read Mode (For Image Scanners Only) - Provides the read mode in scanner speed and image resolution parameters.
Light Source - Infrared (pencil read) or Red (Ink read).
Archive Image Scaling (For Image Scanners Only) - None, 200 DPI, 240 DPI, 300 DPI, 400 DPI, or 600 DPI, depending on the option selected in the Application Settings dialog box.
Enable iNAME - Never, Before User Exits, or After User Exits.
Enabled Image (For Image Scanners Only) - Top/Bottom, Top Only, or None, depending on the option selected in the dialog box.
Read cell spacing - There are two read cell spacing groups:166, .166 (48 cell), .200, offset .200, .200 line read, or .300 line read.
OMR From Image (For Image Scanners Only) - .166, .166 (48 cell), .200, offset .200, .200 line read, or .300 line read, depending on the option selected in the dialog box.
OMR From Scanner - .166, .200, offset .200, .200 line read, or .300 line read, depending on the option selected in the dialog box.
Do not process backside image – Enabled or Disabled
NCS Header Translation Sentinel: Visible character defined or Disabled.
ScanFlex(For Image Scanners Only) Enabled, Enabled Not Present, or Disabled.
Minimum Grayboxes - Enabled or Disabled.
Timing Mark Height/Width Checking - Enabled or Disabled.
OMR/Merge Horizontal Adjustment (For Image Scanners Only)
Form ID Adjust Timing Mark 1 - Enabled or Disabled.
Form ID Adjust Timing Mark End - Enabled or Disabled.
Length for Thickness Measurement - A numeric sheet length (e.g., 8.5 inch Sheet) depending on the option selected in the dialog box.
Form ID Matching - Normal, Enhanced, or Exact, depending on the option selected in the Form ID Matching dialog box.
Scanning Read Characteristics - This lists the settings currently defined in the application Read Controls dialog box.
Application Read Level Control - None, Keyword, or Absolute, depending on what is selected for Read Controls, Scan Time Read Parameters Control.
Bubble read controls
Mark threshold - Light, Normal, Dark, or a numeric value, 3 - 10.
Discrimination margin - Low, Medium, High or a numeric value, 3 - 15.
For Mark threshold and Discrimination margin, the values listed here can be different than the values listed under Default Application Context, Scanning Options, Bubble read controls (below). This is because if Application Read Level Control is Keyword or Absolute, the scanning operator can change the values to be different from the application definition, by using the Scanning Options at scanning time.
Discrimination cutoff - numeric value, 10 - 15.
Form ID / Litho threshold - numeric value, 6 - 10.
Check mark read controls (For Image Scanners Only).
Mark threshold - Light, Normal, Dark, or a numeric value, 3 - 10.
Discrimination margin - Low, Medium, High or a numeric value, 3 - 15.
For Mark threshold and Discrimination margin, the values listed here can be different than the values listed under Default Application Context, Scanning Options, Bubble read controls (below). This is because if Application Read Level Control is Keyword or Absolute, the scanning operator can change the values to be different from the application definition, by using the Scanning Options at scanning time.
Discrimination cutoff - numeric value, 10 - 15.
Tick mark read controls (For Image Scanners Only).
Mark threshold - Light, Normal, Dark, or a numeric value, 3 - 10.
Discrimination margin - Low, Medium, High or a numeric value, 3 - 15.
For Mark threshold and Discrimination margin, the values listed here can be different than the values listed under Default Application Context, Scanning Options, Bubble read controls (below). This is because if Application Read Level Control is Keyword or Absolute, the scanning operator can change the values to be different from the application definition, by using the Scanning Options at scanning time.
Discrimination cutoff - numeric value, 10 - 15.
Advanced Application Settings - This lists settings currently defined in the Advanced Application Settings dialog box.
Image Quality Sentry Settings - blank or "Disabled via Registry" if applicable.
Streak Protection - xx%, percentage calculated from slider control. The highest percentage allowed for this is 90, not 100. 0% (zero) means both Streak Protection and OMR Protection are turned off. OMR Protection does not have it's own control. OMR Protection is on when Streak Protection is greater than zero; when OMR Protection is on, it uses an internally-controlled value that you cannot set.
Overall Protection - xx%, percentage calculated from slider control. 0% (zero) means it is turned off.
Skip Timing Track - Yes or No.
Perform OMR Dark Check - Yes or No.