The following is a list of limits for various elements of a ScanTools application or profile. Some actual values achieved may be limited by the amount of memory available to ScanTools software.
For one application |
|
|
Documents per application |
255 |
|
Output Record Formats per application |
255 |
|
Translate tables and/or Literal strings per application |
8,192 |
|
For one document |
|
|
Sheets per document |
99 |
|
For one Sheet |
|
|
Timing marks per side of sheet |
125 |
|
Form ID marks per sheet |
48 |
|
Skew marks per sheet |
6 |
Single-sided sheet, 6 skew marks on one side. Dual-sided sheet: 6 marks total for both sides. |
Grids per sheet |
999 |
|
Bar codes read per sheet |
|
|
Hardware Bar Code I: |
4 |
(not on OpScan iNSIGHT, 5000i, iNSIGHT 20, iNSIGHT 30, OpScan 2/3/4, or EZData) |
Hardware Bar Code II: |
6 |
(not on iNSIGHT 20, iNSIGHT 30 or EZData) |
Software Bar Code: |
No limit |
(OpScan iNSIGHT with Image, 5000i, iNSIGHT 20, or iNSIGHT 30 only) |
For one output record format |
|
|
Fields per output record |
999 |
|
User-defined characters per output record |
9,957 |
(+ 40 character NCS Header + 2 CR/LF = 9,999 total characters) |
User-defined characters per output record (if image header fields are defined) |
9,869 |
(+ 40 character NCS Header + 88 character image header + 2 CR/LF = 9,999 total characters) |
For one output field |
|
|
Characters per alphanumeric field |
1,000 |
|
Characters per numeric field |
1,000 |
|
Characters per 1- or 2-digit item field |
1,000 |
|
Characters per date field |
4, 6, or 8 |
|
Characters per evaluate field |
100 |
|
For one Summation field |
|
|
Maximum value supported per Summation field |
2,147,483,647 |
(results are undefined if the sum exceeds 2,147,483,647) |
Characters per Min: or Max: area |
10 |
|
For one OMR grid |
|
|
Responses per binary grid |
32 |
(or 31 + parity) |
Segments in linked grid |
64 |
|
For one graybox |
|
|
Maximum output length (in characters) |
999 |
|
For one translate table |
|
|
Entries per translate table |
10,000 |
+ omit + multiple |
Characters per entry |
99 |
|
Characters per translate table name |
40 |
|
For one literal string |
|
|
Characters per literal string |
99 |
|
For one edit profile |
|
|
Translate tables per output field |
12 |
|
For one score profile |
|
|
Subtests per document |
99 |
|
Items per subtest |
999 |
|
For the master clip file (.tif) |
|
|
Maximum image size |
4 gigabyte |
|
See Help on Help for additional information on using this help file. See Scantron Technical Support for additional information on technical support and training options. See the ScanTools Suite System Requirements for further details on hardware and software requirements. ScanTools is a suite of products; the specific information you want may appear in the help for a different module. If you don't find what you're looking for here, try one of the following:
|
Scantron Corporation
Customer Service (forms, products, and services): 1-800-SCANTRON (722-6876) Technical Support: 1-800-445-3141 |
|
Copyright © 1998-2012 Scantron Corporation. All rights reserved. Use permitted only under license. www.scantron.com. No part of the Help or user guides may be reproduced in any form, or by any means, without express permission from Scantron Corporation. LINKS TO THIRD PARTY SITES This help system may contain links to third party websites ("Linked Sites"). The Linked Sites are not under the control of Scantron and Scantron is not responsible for the content of any Linked Site, including without limitation any link contained in a Linked Site or any changes or modifications to a Linked Site. Scantron is not responsible for web casting or any other form of transmission received from any Linked Site. Scantron provides Users with the ability to link the Assessment System to the Linked Sites as a convenience to you, and the inclusion of any link does not imply endorsement by Scantron of the Linked Site or any association with its operators. |