You are here: Programmers Reference > Programmer's Reference > ClipHelper Interface > ManualBitoneThreshold property

ClipHelper.ManualBitoneThreshold property

Read-Write property.

Type: Long

For Bitone Clips Only; ClipDepth is Bitone and when ClipHelper.BitoneThresholdType property is dataManualBitone: Allows you to obtain or set the bitone threshold point value for this clip. Use this to optimize defining the bitone point to generate the cleanest background while keeping the significant data.

This is the same setting as the Manual Bitone Threshold in the ScanTools Plus Application Definition Clip Attributes or Image Clips dialogs.

Valid

See ScanEventArgs and ScanningManager Events Valid Combinations.

IDL

propget, HRESULT ManualBitoneThreshold([out, retval] long* pVal);

propput, HRESULT ManualBitoneThreshold([in, retval] long pVal);

Values

0 – 255.

0 = black and 255 = white.

Default is 0; except if Whole Sheet clip, then uses the value from ScanTools application definition Image Clips dialog.

See also

Capture Image Clips under Solution Control

ClipAttributes Structure

 

 

See Help on Help for additional information on using this help file.

See Scantron Technical Support for additional information on technical support and training options.

See the ScanTools Suite System Requirements for further details on hardware and software requirements.

ScanTools is a suite of products; the specific information you want may appear in the help for a different module. If you don't find what you're looking for here, try one of the following:

 

Scantron Corporation

Customer Service (forms, products, and services):

1-800-SCANTRON (722-6876)

www.scantron.com

Technical Support:

1-800-445-3141

support@scantron.com

Copyright © 1998-2012 Scantron Corporation. All rights reserved. Use permitted only under license. www.scantron.com. No part of the Help or user guides may be reproduced in any form, or by any means, without express permission from Scantron Corporation.

LINKS TO THIRD PARTY SITES

This help system may contain links to third party websites ("Linked Sites"). The Linked Sites are not under the control of Scantron and Scantron is not responsible for the content of any Linked Site, including without limitation any link contained in a Linked Site or any changes or modifications to a Linked Site. Scantron is not responsible for web casting or any other form of transmission received from any Linked Site. Scantron provides Users with the ability to link the Assessment System to the Linked Sites as a convenience to you, and the inclusion of any link does not imply endorsement by Scantron of the Linked Site or any association with its operators.