ScantronScantron.Oledb Provider Specific. The EDIT_PROFILE rowset describes
the contents of a ScanTools Plus edit profile. This schema rowset provides
read-only access to the information stored in the edit profile (*.
GUID: DBSCHEMA_EDIT_PROFILE
Number of restriction columns: 5
Restriction columns: TABLE_CATALOG, TABLE_SCHEMA, TABLE_NAME, COLUMN_NAME, ORDINAL
Default sort order: Document ordinal, column ordinal, partial edit starting position
Column name | Type indicator | Description |
---|---|---|
TABLE_CATALOG |
DBTYPE_WSTR |
NULL |
TABLE_SCHEMA |
DBTYPE_WSTR |
NULL |
TABLE_NAME |
DBTYPE_WSTR |
Name of the document |
COLUMN_NAME |
DBTYPE_WSTR |
Name of the field being edited |
SHEET_NUMBER |
DBTYPE_UI4 |
Sheet number in a booklet where the edit ends. Always one except in the case of booklet documents. |
ORDINAL |
DBTYPE_UI4 |
One-based ordinal of the edit; all edits in all documents contained in the profile. Changes to the edit profile can cause this value to change. |
START_POSITION |
DBTYPE_UI4 |
Start position of the edit, measured from first character in the field |
LENGTH |
DBTYPE_UI4 |
Length of the edit |
COMPLETENESS_EDIT |
DBTYPE_UI1 |
One of the values in Completeness Edit enumerated datatype. See Completeness Edit Enumeration. |
MAX_OMITS |
DBTYPE_UI4 |
Maximum number of omits allowed in the field. (only valid for 1 and 2 digit item fields). |
MAX_MULTS |
DBTYPE_UI4 |
Maximum number of multiples allowed in the field (only valid for 1 and 2 digit item fields). |
LOWER_BOUND |
DBTYPE_WSTR |
Lower bound for range check, or NULL to indicate no lower bound |
UPPER_BOUND |
DBTYPE_WSTR |
Upper bound for range check, or NULL to indicate no upper bound |
IS_ALWAYS_DISPLAY |
DBTYPE_BOOL |
If true, field is always shown in the editor |
IS_BLANK_VALID |
DBTYPE_BOOL |
If true, a blank field passes edit |
IS_OPTIONAL |
DBTYPE_BOOL |
If true, correction is optional |
IS_GRAYBOX |
DBTYPE_BOOL |
If true, this is a graybox edit |
GRAYBOX_LEVEL |
DBTYPE_UI4 |
Cutoff level for greybox edits |
MILLENNIUM_CUTOFF_VALUE |
DBTYPE_UI4 |
For date fields with a 2 digit year, cutoff value for interpreting a year as 19xx rather than 20xx |
STOP_SCAN_ON_FAIL |
DBTYPE_BOOL |
If true, stop scanner on edit failure |
SELECT_ON_FAIL |
DBTYPE_UI1 |
Enumerated value for stack destination of sheet, as defined in Stacker enum. |
SELECT_ALL_ON_FAIL |
DBTYPE_BOOL |
If true, all remaining sheets in booklet sent to the Select_On_Fail stacker |
FLAG_RECORD_ON_FAIL |
DBTYPE_BOOL |
If true, flag record on failure |
REJECT_RECORD_ON_FAIL |
DBTYPE_BOOL |
If true, reject record on failure |
PRINT_FIELD_ON_FAIL |
DBTYPE_WSTR |
If not blank, send contents of named field to transport printer on failure |
PRINT_TEXT_ON_FAIL |
DBTYPE_WSTR |
Literal string to print on edit failure |
MAX_MARK_INTENSITY |
DBTYPE_UI4 |
Maximum allowable percentage of light marks |
REQUIRE_DOUBLE_KEY |
DBTYPE_BOOL |
If true, require double key editing |
REPLACE_TYPE |
DBTYPE_WSTR |
String of N, L ,T or A characters defining up to 4 different replacement actions N – None L – Leading T – Trailing A – All |
REPLACE_FROM |
DBTYPE_WSTR |
String of up to 4 characters to be replaced, as specified by ReplaceType and ReplaceTo |
REPLACE_TO |
DBTYPE_WSTR |
Replacement characters to use in conjunction with ReplaceType and ReplaceFrom |
See Using Restrictions on Schema Rowsets for information about Filtering rows of EDIT_PROFILE Rowset.
See Help on Help for additional information on using this help file. See Scantron Technical Support for additional information on technical support and training options. See the ScanTools Suite System Requirements for further details on hardware and software requirements. ScanTools is a suite of products; the specific information you want may appear in the help for a different module. If you don't find what you're looking for here, try one of the following:
|
Scantron Corporation
Customer Service (forms, products, and services): 1-800-SCANTRON (722-6876) Technical Support: 1-800-445-3141 |
|
Copyright © 1998-2012 Scantron Corporation. All rights reserved. Use permitted only under license. www.scantron.com. No part of the Help or user guides may be reproduced in any form, or by any means, without express permission from Scantron Corporation. LINKS TO THIRD PARTY SITES This help system may contain links to third party websites ("Linked Sites"). The Linked Sites are not under the control of Scantron and Scantron is not responsible for the content of any Linked Site, including without limitation any link contained in a Linked Site or any changes or modifications to a Linked Site. Scantron is not responsible for web casting or any other form of transmission received from any Linked Site. Scantron provides Users with the ability to link the Assessment System to the Linked Sites as a convenience to you, and the inclusion of any link does not imply endorsement by Scantron of the Linked Site or any association with its operators. |