Sets the OMR read-level and the mark style for the following:
See ScanEventArgs and ScanningManager Events Valid Combinations.
HRESULT SetBubble(
[in] long Cell;
[in] long Track;
[in] SideOfSheet sos;
[BubbleValue Value);
Cell |
1 |
Maximum cell position. OmrBuffer.MaxCell property. This is the read cell position of the bubble along the X-axis of the form. |
0 (zero) |
Sets all read cells for one specific timing mark position (Track, below), to the Value used in BubbleValue. |
|
Track |
1 |
Timing mark position. OmrBuffer.BackTimingMarks property or OmrBuffer.FrontTimingMarks property. This is the timing mark position of the bubble along the Y-axis of the form. |
0 (zero) | Sets all read cells in all tracks (the entire buffer) to the Value used in BubbleValue. | |
SideOfSheet |
const int sosTop | top side |
const int sosBottom | bottom side | |
BubbleValue structure | Value | use the enum OMRLevel |
Zero – F | The read-level for the cell. | |
NotBuilt | The bubble has not been built. This clears out any previous value. | |
Style | use the enum BubbleType | |
btBubble | Standard OMR bubble, circle or oval. | |
btCheckMark |
Check Mark or X mark, rectangular area for an X, check, or other mark. For Image Scanners ONLY, and the side of sheet must have image enabled. |
|
btTickMark |
Tick mark compatible with line read heads. A rectangular response area approximately as wide as a normal OMR position, but only as high as a thick pencil mark. A single horizontal stroke is used to indicate a response. For Image Scanners ONLY, and the side of sheet must have image enabled. |
See Help on Help for additional information on using this help file. See Scantron Technical Support for additional information on technical support and training options. See the ScanTools Suite System Requirements for further details on hardware and software requirements. ScanTools is a suite of products; the specific information you want may appear in the help for a different module. If you don't find what you're looking for here, try one of the following:
|
Scantron Corporation
Customer Service (forms, products, and services): 1-800-SCANTRON (722-6876) Technical Support: 1-800-445-3141 |
|
Copyright © 1998-2012 Scantron Corporation. All rights reserved. Use permitted only under license. www.scantron.com. No part of the Help or user guides may be reproduced in any form, or by any means, without express permission from Scantron Corporation. LINKS TO THIRD PARTY SITES This help system may contain links to third party websites ("Linked Sites"). The Linked Sites are not under the control of Scantron and Scantron is not responsible for the content of any Linked Site, including without limitation any link contained in a Linked Site or any changes or modifications to a Linked Site. Scantron is not responsible for web casting or any other form of transmission received from any Linked Site. Scantron provides Users with the ability to link the Assessment System to the Linked Sites as a convenience to you, and the inclusion of any link does not imply endorsement by Scantron of the Linked Site or any association with its operators. |